BSXZP - DEOX IT-D5, D5S-6
- MSDS: BSXZP
- Manufacturer: CAIG LABORATORIES INC
- Product Name: DEOX IT-D5, D5S-6
- National Stock Number: 6850-00N042795
Product Identification
Product ID:DEOX IT-D5, D5S-6
MSDS Date:06/01/1992
FSC:6850
NIIN:00N042795
MSDS Number: BSXZP
Responsible Party
SAND DIEGO, CA 92127-1904
US
Emergency Phone: 800-356-3129
Info Phone: 800-441-3637
Preparer: MARK K. LOHKEMPER
Cage: 55403
Contractor
Telephone: 858-486-8388
Cage: 55403
Ingredients
CLEANSE AFFECTED AREA(S) WITH MILD SOAP
RTECS: 9999999ZZ
DO NOT INDUCE VOMITING, KEEP PERSON WARM, QUIET AND
RTECS: 9999999ZZ
VOMIT CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE
RTECS: 9999999ZZ
BY VENTILATION, CLEAN UP OILY RESIDUE WITH ANY
RTECS: 9999999ZZ
LOCATIONS MUST BE USED.
RTECS: 9999999ZZ
USE ONLY AS DIRECTED.
RTECS: 9999999ZZ
40C, 104F.
CAS: 64742-88-7
Fraction By Weight: 75%
OSHA PEL 100 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
ETHANE, 1,1,1-DIFLUORO-; (DIFLUOROETHANE)
CAS: 75-37-6
RTECS: KI1410000
Fraction By Weight: 20%
OSHA PEL N/K
ACGIH TLV: N/K
DEOXIT D100L LIQUID
Fraction By Weight: 5%
OSHA PEL N/K
ACGIH TLV: N/K
NO SPECIFIC INTERVENTION
RTECS: 9999999ZZ
HAZARDOUS BY INGESTION. HOWEVER, INGESTION OF
RTECS: 9999999ZZ
DIARRHEA. ASPIRATION OF MATERIAL INTO THE LUNGS CAN
RTECS: 9999999ZZ
FOR DIRECT CNTCT, HOLD EYELIDS APART &
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ING 2:INHAL: VAP IS HVR/AIR & CAN
CAUSE SUFFOCATION BY REDUCING OXYGEN AVAIL FOR BRTHG. BRTHG HIGH
CONC OF VAP MAY CAUSE LT-HEAD, DIZZ, SHORTNESS OF BREATH, & MAY
LEAD TO NARCOSIS, CARDIAC IRREGULARIT IES, UNCONSCIOUSNESS OR
DEATH. ING 1: INHAL:LOW DEGREE OF TOXICITY, BUT BRTHG HIGH CONC OF
VAPS OR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:MISTS MAY CAUSE IRRIT OF THE NOSE &
THROAT & SIGNS OF NERV SYS DEPRESS (E.G., HDCH, DROWSINESS, DIZZ) &
POSS UNCON, & EVEN DEATH. EYE: IS AN EYE IRRIT. DIRECT CNTCT W/LIQ
EXPOS TO VAPS OR MIS TS MAY CAUSE STINGING, TEARING REDNESS &
SWELLING. SKIN: PRLNGD/RPTD CNTCT CAN CAUSE MOD IRRIT, DEFAT, (ING
4)
Medical Cond Aggravated by Exposure:RESPIRATORY SYMPTOMS ASSOCIATED
WITH PRE- EXISTING LUNG DISREDERS (E.G., ASTHMA-LIKE CONDITIONS)
MAY BE AGGRAVATED BY EXPOSURE TO INGREDIENT 1.
First Aid
First Aid:INHAL:IF RESP SYMPS OR OTHER SYMPS OF EXPOSURE DEVELOP, MOVE
VICTIM AWAY FROM SOURCE OF EXPOSURE & INTO FRESH AIR. IF SYMPS
PERSIST, SEEK IMMED MED ATTN. IF VICITIM IS NOT BRTHG, IMMED BEGIN
ARTF RESP . IF BRTHG DFCLTS DEVELOP, OXYGEN SHLD BE ADMIN, SEEK MED
ATTN. EYE:MOVE VICTIM AWAY FROM EXPOS & INTO FRESH AIR. IF
IRRIT/REDNESS DEVELOPS, FLUSH EYES W/CLEAN WATER & SEEK MED ATTN.
(ING 7)
Fire Fighting
Flash Point:104F,40C (ING 1)
Lower Limits:1%
Upper Limits:6%
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, HALON, POLAR OR
ALCOHOL FOAM, OR WATER SPRAY IS RECOMMENDED. WATER MAY BE
INEFFECITIVE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. MOVE UNDAMAGED CNTNRS FROM FIRE AREA IF IT CAN DONE WITHOUT RISK.
AVOID SPREADING BURNING LIQ (SUPP DATA)
Unusual Fire/Explosion Hazard:INGRED 1 IS FLAMM & MAY BE IGNIT BY HEAT/
SPARKS/FLAME/OTHER SOURCES OF IGNIT (E.G. STATIC ELECTRICITY, PILOT
LIGHTS, MECH/ELEC EQUIP). VAPS MAY (SUPP DATA)
Accidental Release
Spill Release Procedures:FLAMM. KEEP AWAY FROM ALL SOURCES OF IGNIT &
HOT SURFS. SPILLED MATL MAY BE ABSORBED INTO ANY ABSORB MATL. WEAR
APPROP PROT EQUIP INCL NIOSH/MSHA APPRVD RESP PROT AS CNDNTS
WARRANT. VENT AREA TILL ODO R IS GONE. AFTER ING 1 HAS BEEN
REMOVED(ING 11)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT EXPOSE ANY AEROSOL CAN TO
SUNLIGHT/ TEMP >120F TO PVNT POSS BURNING. ALL AEROSOL CAUTIONS
APPLY-USE IN WELL VENT AREAS. DO NOT BRTH SMOKE/FUMES
Other Precautions:WEAR APPROP PROT EQUIPMENT. USE AND STORE IN COOL,
DRY, WELL VENTILATED AREAS AWAY FROM HEAT, HOT SURFACES AND ALL
SOURCES OF IGNITION. PROT CNTNRS FROM PHYSICAL DMG. INDOOR STORAGE
SHLD MEET OSHA STD S & APPOP CODES. AS W/ANY CHEM -(ING 13)
Exposure Controls
Respiratory Protection:NOT NECESSARY UNLESS USED IN AN UNVENTILATED
AREA OR IN HIGH CONCENTRATIONS. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:KEEP EXPOSURE BELOW LIMIT. KEEP WINDOWS OPEN. LOC EXHST:
WHEN USED REPEATLY IN QUANTITY. ELEC SYS SAFE FOR SUCH (ING 12)
Protective Gloves:NITRILE RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM SAFETY GOGGLES
Other Protective Equipment:NOT NECESSARY WITH ADEQUATE VENTILATION.
Work Hygienic Practices:AVOID BREATHING VAPORS AND CONTACT WITH SKIN OR
EYES, USE ADEQUATE VENTILATION. WASH HANDS AFTER USE.
Supplemental Safety and Health
FIRE FIGHT PROC: W/WATER USED FOR COOLING PURPOSES. EXPLO HAZ: TRAVEL
CONSIDERABLE DISTANCES TO A SOURCE OF IGNIT WHERE THEY MAY IGNITE,
FLASHBACK OR EXPLODE. VAP/AIR EXPLO HAZ INDOORS/ OUTDOORS OR IN
SEWERS. VAP ARE HVR/AIR & MAY ACCUM INLOW AREAS. IF CNTNR IS NOT
PROPERLY COOLED, IT MAY EXPLODE IN THE HEAT OF A FIRE
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:320F,160C
Vapor Pres:<12 @ 100F
Spec Gravity:0.750 @ 60F
Evaporation Rate & Reference:< 0.1 (BUTYL ACETATE=1)
Solubility in Water:NEGLGIBLE
Appearance and Odor:LIGHT PINK; SLIGHT ETHEREAL/HYDROCARBON ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
AVOID ALL POSSIBLE SOURCES OF IGNITION.
Hazardous Decomposition Products:COMBUSTION MAY YIELD CARBON MONOXIDE
&/OR CARBON DIOXIDE VARIOUS HYDROCARBONS.
Disposal
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS. EPA HAZ WASTE #'S F001 @ F002 MAY APPLY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.